Instruction manual
MATRIX 200™ REFERENCE MANUAL
2
Setup (Function 3)
Once entered, the imager automatically performs Image Acquisition parameter calibration for
the specific code presented to it.
The Setup LED will blink until the procedure is completed.
The Setup procedure ends when the Image Acquisition parameters are successfully saved in
the reader memory, the Setup LED will remain on continuously and Matrix 200™ emits 3 high
pitched beeps.
If the calibration cannot be reached after a timeout of about 5 (five) seconds Matrix 200™ will
exit without saving the parameters to memory, the Setup LED will not
remain on continuously
but it will just stop blinking. In this case Matrix 200™ emits a long low pitched beep.
Learn (Function 4)
Once entered, the imager starts a procedure to automatically detect and recognize codes
which are presented to it.
The Learn LED will blink until the procedure is completed.
The Learn procedure ends when the Image Processing and Decoding parameters are
successfully saved in the reader memory, the Learn LED will remain on continuously and
Matrix 200™ emits 3 high pitched beeps.
If the calibration cannot be reached after a timeout of about 3 (three) minutes, Matrix 200™ will
exit without saving the parameters to memory, the Learn LED will not
remain on continuously
but it will just stop blinking. In this case Matrix 200™ emits a long low pitched beep.
2.5 MODEL DESCRIPTION
The Matrix 200™ reader is available in different versions according to the following
characteristics:
MATRIX 200 XXX-
X
XX
Illuminators
1 = Internal Illuminator
Focus Distance
1 = Near
2 = Medium
3 = Far
4
= UHD
Sensor Size
2 = WVGA (1280x1024)
Reading Window
0 = 90°
1 = Straight
Interface
0 = Serial
2 = USB
Options
0 = Standard
1 = ESD Safe
2 = ESD Safe + YAG Cut Filters
24