4.2.3 Reading Mask
In VisiSet™, if the Array Layout Monitor parameter in the Display folder is enabled, it
changes the appearance of the reading mask.
Array Layout Monitor Enabled
If the Array Layout Monitor parameter is enabled, on row one, the display shows the result of
the reading phase: code content, or read event message.
Row two shows the reading phase counter and read rate counting from the last restart of the
system. These values are reset if the reader configuration is changed or a manual reset of
the statistics is performed (Init Counters).
On row three, the reading mask for the master and slave readers (ordered from left to right)
is shown with the numbers 0 and 1. A successful read is presented as a 1 for the readers
who have read the code.
The network state on row four has the same meaning as in par. 4.2.2.
Row 1: Last Reading Result
Row 2: Reading Phase Count and Statistics
Row 3: Reading Mask
Row 4: Network State
1234567890
P=0000001 GR=100.00%
110000000000000
Good Read
Master and
Slave 1
*****----------
1234567890
P=0000001 GR=100.00%
000110000000000
Good Read
Slave 3 and
Slave 4
*****----------
No Read
P=0000002 GR=50.00%
000000000000000
No Read
*****----------
Array Layout Monitor Disabled
If the Array Layout Monitor parameter is disabled, on row one, the display shows the result of
the reading phase: code content, or read event message.
Row two shows the reading statistics based on the last 100 reading phases: Good Read,
No Read, Multiple Read (more codes read than expected) and Partial Read (less codes read
than expected). The percentages range from 00 to 99.
On row three (and four which is not used for STS400™), the reading mask for the master
and slave readers (ordered from left to right) is shown with the numbers 0 and 1. A
successful read is presented as a 1 for the readers who have read the code.