Installation manual

ELECTRICAL CONNECTIONS
35
3
3.6 AUXILIARY RS232 INTERFACE
The RS232 auxiliary interface is available for Point-to-Point connections. When it is
connected to the host computer it allows both transmission of code data and reader
configuration by VisiSetâ„¢.
The parameters relative to the aux interface (baud rate, data bits, etc.) as well as particular
communication modes such as LOCAL ECHO can be defined through the Communication
folder of the VisiSetâ„¢ utility program.
The 9-pin female Auxiliary Interface connector inside the CBX is the preferred connector for
device configuration or communication monitoring.
5
1
69
Figure 11 - 9-pin female connector
If permanent system wiring is required, the following pins are used to connect the RS232
auxiliary interface:
CBX500 ATS Function
RX Auxiliary Interface Receive Data
TX Auxiliary Interface Transmit Data
SGND Auxiliary Interface Reference
RX TX
Reference
USER INTERFACE
Figure 12 - RS232 Auxiliary Interface Connections
NOTE
Do not connect the Aux Interface to the CBX spring clamp connectors and
the 9-pin connector simultaneously.