Installation manual
STS400™ INSTALLATION MANUAL
30
3
3.2 CBX CONNECTION BOX PINOUT
The STS400™s all connect to the CBX500 ATS-001 as shown in the previous diagram. The
table below gives the pinout of the CBX terminal block connectors.
CBX500 ATS Terminal Block Connectors
Input Power
Vdc Power Supply Input Voltage +
GND Power Supply Input Voltage -
Earth Protection Earth Ground
Inputs
+V Power Source – External Trigger
I1A External Trigger A (polarity insensitive)
I1B External Trigger B (polarity insensitive)
-V Power Reference – External Trigger
+V Power Source – Inputs
I2A Input 2 A (polarity insensitive)
I2B Input 2 B (polarity insensitive)
-V Power Reference – Inputs
Outputs
+V Power Source - Outputs
-V Power Reference - Outputs
O1+ Output 1 +
O1- Output 1 -
O2+ Output 2 +
O2- Output 2 -
Auxiliary Interface
TX Auxiliary Interface TX
RX Auxiliary Interface RX
SGND Auxiliary Interface Reference
ID-NET™
REF Network Reference
ID+ ID-NET™ network +
ID- ID-NET™ network -
Shield Network Cable Shield
Main Interface
RS232
RS485
Full-Duplex
TX TX+
RX
*RX+
RTS TX-
CTS
*RX-
SGND SGND
* Do not leave floating, see par. 3.5.2 for connection details.
NOTE
To avoid electromagnetic interference when the reader is connected to a
CBX connection box, verify the jumper positions in the CBX as indicated in
its Installation Manual.