In the C-BOX 300 the warning LED is repeated in the base.
Figure 4.13 LED Indicators in base
The internal LEDs of the C-BOX 300 (see Figure 17) indicate the following:
POWER ON (red):
indicates the C-BOX 300 is connected to the power supply
and the power switch i s ON.
WARNING (red):
indicates a warning or error condition. It is ON when a con-
nection procedure is in progress (the system is busy), during
a GET/TEST/SEND procedure or during the Configuration
Mode. It flashes when an error condition occurs. Normally
this LED should be OFF.
TX, LD3 (green):
indicate the Profibus Network activity. When communication
takes place, these LEDs will blink slight ly.
LD2 (green):
OFF = Bus off-line or power not supplied.
ON = Bus in Data Exchange Mode.
Flashing = Bus in Clear Mode.
LD1 (red):
OFF = No er ror or power not supplied.
ON = Error in initialisation of Profibus ASIC.
Flashing = Error in configuration data and / or in user para-
meter data.
Warning LED