Instruction manual
Connection box C-BOX 300
Installation
S
ubject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
P
epperl+Fuchs Group • Tel.: Germany (06 21) 7 76-0 • USA (330) 4 25 35 55 • Singapore 7 79 90 91 • Internet http://www.pepperl-fuchs.com
Date od issue 08/15/2003
20
The procedure to enable the GET/TEST/SEND function is the following:
1. Press both the buttons left and right simultaneously for at least one second; the
warning LED turnes ON.
2. Release the buttons.
3. Press the left button corresponding to the GET function, the center button
corresponding to the TEST function or the right button corresponding to the
SEND function.
GET – (left button):
The C-BOX 300 reads the current scanner configuration and permanently copies it in
its internal memory (EEPROM). The C-BOX 300 preserves this configuration also
when switched off (non volatile).
TEST - (center button):
The C-BOX 300 forces the scanner to run the "Test Operating Mode" (refer to the
scanner installation manual for details).
Press any button to quit the "Test Operating Mode" and return the scanner to the
normal operating mode.
SEND - (right button):
The C-BOX 300 sends the configuration previously stored in its internal permanent
memory to the scanners EEPROM.
4.12 LED Indicators
Figure 4.12 LED Indicators in cover
Once the buttons are released in step 1, a ten-second timeout starts.
If no button is pressed within this time (no function is selected), the
procedure will be cancelled.
The C-Box 300 warning LED (Figure 4.12) is turned OFF at the end of
each procedure.
Power on Tx LD1 LD2 LD3
Warning LED