Instruction manual
Connection box C-BOX 300
Installation
S
ubject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany (06 21) 7 76-0 • USA (330) 4 25 35 55 • Singapore 7 79 90 91 • Internet http://www.pepperl-fuchs.com
Date od issue 08/15/2003
19
4.11 OPERATING MODES
With the C-BOX 300, three operating modes are possible:
4.11.3 Normal Operation:
Once the connection procedure is completed (the warning LED is OFF), the C-BOX
300 is ready to receive code strings from the scanners RS 232 main interface. Then,
it converts them to the Profibus DP network.
GET/TEST/SEND:
Through the C-BOX 300 internal buttons it is possible to communicate with the
scanner to perform one of the following operations:
• Get scanner configuration
• Force the scanner in TEST mode
• Send a configuration to the scanner
At the end of each operation the scanner returns to the previous operating mode.
GET/TEST/SEND Functions
The C-BOX 300 has three internal function buttons.
Figure 4.11 Buttons GET/TEST/SEND
9-pin connector pinout
Pin Name Description
2 RX C-BOX 300 Conf iguration
3
TX
C-BOX 300 Conf iguration
5
SGND Signal Ground
When the C-BOX 300 configuration is completed, remember to replace
the Configuration switch in the Normal Operation position.