4.6 Chassis Grounding Jumper Settings
The scanner chassis grounding method can be selected by positioning a jumper (see
Figure 4.7). In this way the scanner chassis can be connected to earth ground (only
if pins 7 or 8 are connected to a good earth ground) or to the power supply ground
signal. The scanner chassis can also be left floating but, in this case, the jumper must
be removed.
Figure 4.7 Jumper settings for chassis grounding
The C-BOX 300 is now installed which completes the electrical connections for your
scanning system.
Refer to the scanner Installation Manual for details.
Pin Description
1, 3, 5 VS
2, 4, 6 GND
7, 8 EARTH GROUND
9 ... 12, 20, 33, 34, 40 Reserved
21 OUT1+
23 OUT2+
27 EXT TRIG+
28 EXT TRIG-
35 TXA
37 RXA
39 SGND
VB10, VB12, VB14
22, 24 OUT REF
25, 26, 29, 30, 31, 32 NC
36 RTSA
38 CTSA
Pin 7 or 8 should be connected to the earth ground.
EARTH
GROUND
(default)
GND floating