Instruction manual

Connection box C-BOX 300
Installation
S
ubject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
P
epperl+Fuchs Group • Tel.: Germany (06 21) 7 76-0 • USA (330) 4 25 35 55 • Singapore 7 79 90 91 • Internet http://www.pepperl-fuchs.com
Date od issue 08/15/2003
14
the C-BOX 300 and the scanner. During this phase, requiring a few seconds, the
warning LED is turned ON. Once the procedure had been completed successfully, the
warning LED is turned OFF.
After sucessful system check, close the C-BOX 300 using the 4 cover screws making
sure the rubber seal is fitted correctly between the parts of the housing.
4.5 Power Supply
Power is supplied to the C-BOX 300 through the pins provided on the spring clamp
connector.
The power switch (see Figure 4.5) switches the power supply ON or OFF for both the
C-BOX 300 and the connected scanner.
Figure 4.5 Power switch ON/OFF positions
Figure 4.6 Power supply connections
The C-BOX 300 spring clamp connector pinouts are indicated in the following table.
The power supply must be between 10 and 30 VDC only.
Pin 1 is also electrically connected to pins 3 and 5, just as pin 2 is
electrically connected to pins 4 and 6. This is useful for external trigger/
inputs connections.
S1
ON
OFF
1
2
VS
GND
GND
V+ (10 ... 30 V DC)
USER INTERFACE
C-BOX