System information

DS2400N QUICK GUIDE
10
STEP 5 – TEST MODE
Use a code suitable to your application to test the system. Alternatively, you can use the Datalogic Test Chart
(Code 39, Code Interleaved 2/5).
1. Enter the Test mode function (F1) by pressing the X-PRESS™ push button.
2. Hold the push button pressed until the F1 LED is on.
3. Release the button to enter the Test mode function.
Once entered, the Bar Graph on the five LEDs is activated and if the scanner starts reading barcodes the
Bar-Graph shows the Good Read Rate. In case of no read condition, only the STATUS LED is on and blinks.
F4
F3
F2
F1
F0
READY
GOOD
T
RIGGER
COM
STATUS
AutoSetup
A
utoLearn
Test Mode
Exit
Figure 7 – X-PRESS™ Interface: Test Mode Function
4. To exit the Test Mode, press the X-PRESS™ push button once.
NOTE
By default, the Test Mode exits automatically after two minutes.