Installation manual
INSTALLATION
2
2.6.2 6000, 8000 Scanners
For the 6k/8k scanner Families, the C-BOX 150 can operate in both point-to-point
single scanner configuration layouts and in a whole cluster of scanners in
Master/Slave layouts.
Master
Slave 2 Slave1
C-BOX 150
BTK-6000
CAB-610X CAB-610X
CAB-60XX
PS
Encoder
CAB-610X
Host
CAB-610X
CAB-610X
CAB-63XX
BTK-6000
Slave 5 Slave 4
Slave 3
PWR-240
CAB-63XX
NOTE
In a Master/Slave layout with a great number of Slaves, a Power
Supply Unit can be connected to the scanners and the C-BOX 150
can accept the scanner power by setting the Power Source Jumper
in the right position. See paragraph 2.4.6
By default, C-BOX 150 is able to perform Backup/Restore of the whole cluster
(Master and Slaves). The following conditions must be met:
1. The Master/Slave network must be either Synchronized or Multidata.
2. The A.S.R. mode must be disabled.
In order to perform Backup/Restore of Master only, the C-BOX 150 Cluster
GET/SEND parameter must be configured to "Master only".
See also WinHost Help online.
21