2.4.1 Power Supply
Power is supplied to the C-BOX 200 through the pins provided on the spring clamp
connector.
The power switch (see Figure 6) switches the power supply ON or OFF for both the
C-BOX 200 and the connected scanner.
ON
OFF
S1
Figure 6 - Power switch ON/OFF positions
C-BOX
1
2
VS
GND
USER INTERFACE
GND
V+ (10 - 30 Vdc)
Figure 7 - Power supply connections
NOTE
Pin 1 is also electrically connected to pins 3 and 5, just as pin 2 is
electrically connected to pins 4 and 6. This is useful for external
trigger/inputs connections.
The power supply must be between 10 and 30 Vdc only.