Instruction manual
A30 QUICKSTART GUIDE
16
OUTPUTS
Three optocoupled general purpose outputs are available. The meaning of the outputs can be
defined by the user. They are typically used either to signal the data collection result or to control
an external lighting system.
The electrical features of the two outputs are the following:
V
CE
= 30 Vdc max.
I
CE
= 40 mA continuous max.; 130 mA pulsed max.
V
CE saturation
= 1 Vdc max. @ 10 mA
P
D
= 80 mW Max. @ 45 °C ambient temp.
The output signals are fully programmable. Refer to the Discrete Output tool section in the
Impact Reference Guide for further details.
OUTPUT CONNECTIONS USING CBX POWER
Note: The strobe signal connection is shared with Output 3. If a non-zero value is defined for the Strobe Pulse Length
value (in VPM – Impact – General), the strobe is active. If the value is zero, Output 3 is active.
CAUTION
Power is available directly to the Output Device, independently from the
Power Supply Switch inside the CBX.
Figure 18 - Open Emitter Output Using CBX Power Figure 19 - Open Collector Output Using CBX Power
CBX500
Function
+V
Power Source - Outputs
O1+
Output 1 +
O1-
Output 1 -
O2+
Output 2 +
O2-
Output 2 -
O3A
Strobe + / Output 3 + (See Note)
O3B
Strobe - / Output 3 -
-V
Power Reference Outputs