CBX ELECTRICAL CONNECTIONS
11
CBX ELECTRICAL CONNECTIONS
All A30 cameras can be connected to a CBX500 connection box using a CAB-SCSxx accessory
cable. These accessory cables terminate in a 19-pin connector on the camera side and in a 25-
pin male D-sub connector on the CBX side.
We recommend making system connections through one of the CBX connection boxes since
they offer the advantages of easy connection, easy device replacement, and filtered reference
signals.
The table below shows the terminal block connections for the CBX500.
CBX500 Terminal Block Connectors
Input Power
Vdc
Power Supply Input Voltage +
GND
Power Supply Input Voltage -
Earth
Protection Earth Ground (See Caution)
Inputs
+V
Power Source – External Trigger
I1A
External Trigger A (polarity insensitive)
I1B
External Trigger B (polarity insensitive)
-V
Power Reference – External Trigger
+V
Power Source – Inputs
I2A
Input 2 A (polarity insensitive)
I2B
Input 2 B (polarity insensitive)
I3A
NOT USED
I4A
NOT USED
I34B
NOT USED
-V
Power Reference – Inputs
Shield
Shield
Network Cable Shield
Outputs
+V
Power Source - Outputs
-V
Power Reference - Outputs
O1+
Output 1 +
O1-
Output 1 -
O2+
Output 2 +
O2-
Output 2 -
O3A
Strobe + / Output 3 + (See Note)
O3B
Strobe - / Output 3 -
RS232 Interface
TX
Transmit
RX
Receive
SGND
Signal Ground (See Caution)
Note: The strobe signal connection is shared with Output 3. If a non-zero value is defined for the Strobe Pulse Length
value (in VPM – Impact – General), the strobe is active. If the value is zero, Output 3 is active.
CAUTION
Do not connect GND and SGND to different (external) ground references.
GND and SGND are internally connected through filtering circuitry which
can be permanently damaged if subjected to voltage drops over 0.8 Vdc.