Hardware manual

HTTP Commands Impact Reference Guide
Datalogic Automation Inc. 6-30
HTTP Commands
This section describes HTTP commands that can be used to send commands to a Datalogic vision device
over a local area network. These commands can be sent to the vision device using a standard Internet
browser.
NOTE: All commands are case sensitive.
To send commands to the camera
1. Start a web browser
2. In the browser's address field, type the camera’s IP Address followed by a forward slash. For example
http://192.168.0.128/
3. Type one of the following commands after the address
HTTP Command What it does
IsOnline Displays True if the camera is currently online
Offline Puts the camera offline, if it is online
status Displays the camera’s current status, including model number,
software version, camera settings and other information.
syslog Displays the most recent fifty entries from the System Log in
reverse date order
syslog/count=nnn Displays the most recent "nnn" entries from the System Log in
reverse date order
unlock Unlocks the camera if it is locked for editing