Hardware manual

General Impact Reference Guide
Datalogic Automation Inc. 2-6
3. When the connection has been made, click the General System Object, click the Setup tab, then click
the General radio button. Enter the new IP Mask and/or IP Address in the appropriate field(s). Record
the new value (along with the serial number) and store it where you can find it again.
4. Click the Diagnostics radio button, then click the Reboot device button. You must reboot to make the
changes take effect in the device or camera.
IP Gateway
The IP Gateway address is used when you want to access an IP Address through a router. You will ordinarily
leave this field blank.
Device Comment
The comment can contain notes about the device or camera such as its function, the physical location, what
it is inspecting, or when it was put into service. This comment is displayed on the Device Selection tab.
Go Online When Device Starts
Check this box if you want the device to go Online when it starts. Any tasks that are loaded are executed,
based on their trigger parameters. To mark which tasks get loaded when the device starts, see “File Manager
Setup Tab” on page 2-37.
Connections
Maximum
The maximum number of users at each level (1 to 100) that can be connected to this device at one
time. Multiple users can connect to one device, but only one user at a time can edit programs or
change data on the device.
Current
The number of users at each level currently connected to the device.
Device Date/Time
This displays the current date and time stored on the Datalogic Impact device. To set the device date and
time to match the client computers, click Synchronize to PC.
NOTE: The device does not automatically adjust for daylight savings time changes. You will need to manu-
ally synchronize it.
Enable Timeout
Here you can define the maximum length of time a task may take to execute and the maximum length of
time the tool will wait for a response from a control panel.
NOTE: Task Timeout applies only to tasks with the Trigger Event set to Image In Event and is effective only
while the device is online and triggering.
Task - When this property is enabled, the Task Timeout value determines how much time the task is
allowed to complete execution before it aborts. See “Vision Program Properties” on page 3-32.