Hardware manual
Impact Reference Guide Code Reader
3-171 Datalogic Automation Inc.
1D Check Digit Sta-
tus (PMA)
If True, the check digit control is enabled to improve decoding safety.
The check digit is generally the last digit aligned to the right of the code
which verifies the validity of the preceding digits. The calculation tech-
nique and number of check digits depends on the code type. The check
digit should be used whenever the code contains one. Applies to
Code39, Interleaved 2 of 5, MSI, Standard 2 of 5, Matrix 2 of 5, and Cod-
abar
1D MSI Check Digit
Status (PMA)
The Check Digit algorithm used depends on the code type.
MSI_ChksumDisable: Disable the algorithm
MSI_ChksumSingleMod10: Use the SingleMod10 algorithm
MSI_ChksumMod11Mod10: Use the Mod 10 + Mod 11algorithm
MSI_ChksumTwoMod10: Use the Two Mod 10 algorithm
The check digit is generally the last digit aligned to the right of the code
which verifies the validity of the preceding digits. The check digit should
be used whenever the code contains one.
1D Check Digit
Transmission
(PMA)
If True, the Check Digit is included in the Output String property. Applies
to Code39, MSI, Standard 2 of 5, Matrix 2 of 5, and Codabar.
1D I25 High Decod-
ing Safety
If True, the tool uses a strict control for decoding this code type.
1D I25 Minimum
number of charac-
ters (PMA)
If the code contains this number of characters or fewer, the tool fails.
Applies to Interleaved 2 of 5.
1D Pharmacode
Output format
(PMA)
The output format for decoded Pharmacodes. The default setting of
Binary is not changed during Training. To use the Encoded property it
must be manually selected on the Properties tab.
Encoded: Output is standard numeric format
Binary: Output is binary format - wide bars correspond to digit 1 and nar-
row bars correspond to digit 0
1D Pharmacode
Decoded Min Value
If the decoded Pharmacode’s value is equal to or less than this, the tool
fails. Valid only when 1D Pharmacode Output format is set to Encoded.
1D Pharmacode
Decoded Max Value
If the decoded Pharmacode’s value is greater than this, the tool fails.
Used only when 1D Pharmacode Output format is set to Encoded.
1D Pharmacode
Colored Check bars
If True, a Pharmacode’s colored bars are checked.
1D Pharmacode
MinBarCount
(PMA)
If the Pharmacode contains this number of bars or fewer, the tool fails.
1D Pharmacode
MaxBarCount
(PMA)
If the Pharmacode contains more than this number of bars, the tool fails.
Input Name What it is