Hardware manual
Impact Reference Guide Code Reader
3-169 Datalogic Automation Inc.
MSI If True, the tool looks for this code type when it runs.
Matrix 2 of 5 If True, the tool looks for this code type when it runs.
EAN/UPC If True, the tool looks for this code type when it runs.
EAN/UPC Add On
2/5
If True, the tool looks for the 2 and 5 supplemental digits added to the
right of the EAN/UPC code when it runs.
Pharmacode (one-
track)
If True, the tool looks for this code type when it runs.
PDF417 If True, the tool looks for this code type when it runs.
MicroPDF If True, the tool looks for this code type when it runs.
Composite Codes If True, the tool looks for this code type when it runs. See “Composite
Codes” on page 3-180
Datamatrix ECC
200, GS1 Datama-
trix ECC 200
If True, the tool looks for this code type when it runs.
QR Codes If True, the tool looks for this code type when it runs.
Micro QR If True, the tool looks for this code type when it runs.
Aztec If True, the tool looks for this code type when it runs.
Maxicode If True, the tool looks for this code type when it runs.
Postal Codes If True, the tool looks for Postal codes when it runs.
Postal Customer
Field Decoding
Select the type of Australia Post Customer Field Decoding from the list
of recognized standards. This input is not set during Training; it must be
selected on the Properties tab.
Postal Minimum Bar
Count (PMA)
If the Postal Code contains this number of bars or fewer, the tool fails.
Postal Maximum
Bar Count (PMA)
If the Postal Code contains more than this number of bars, the tool fails.
Postal Bar Edge
Spacing (PMA)
The sum of the Bar Width + Space Width in pixels.
Postal Code Orien-
tation (PMA)
The code’s orientation.
Any: the code can be in any orientation (this setting takes longer to run)
Horizontal & Vertical: the code is aligned to either the x or y axis (+/-
20°)
Horizontal Only: the code is aligned to the x axis (+/- 20°)
Vertical Only: the code is aligned to the y axis (+/- 20°)
Input Name What it is