Hardware manual
Code Reader Impact Reference Guide
Datalogic Automation Inc. 3-168
Processing Mode When you Train the tool, the Processing Mode for the best results is
automatically selected. Some input properties are only effective when
Advanced mode is selected. These properties are labeled "Processing
Mode Advanced" (PMA) in this table. See “Code Configuration Process-
ing Modes” on page 6-35.
Standard: Normally used for most applications. The magnification may
be highly variable and the position and orientation of the symbol can be
generally unpredictable.
Advanced: Can be used to increase the decode rate on very small or
difficult codes or when the symbol is presented at a fixed magnification
and has known properties such as resolution, number of modules, orien-
tation, minimum code height, etc.
Image Mirroring If True, the tool assumes the external 90 Degree camera mirror acces-
sory is being used.
Identical Codes
Decoding
If True, identical codes (within the same image) are decoded when the
tool runs. A code is considered identical if it has the exact same length,
code type, and data string as one already decoded.
If you set the 1D Advanced Box Improvement to False, you should also
set this property to False to prevent the tool from reading the same code
instance multiple times.
Codabar If True, the tool looks for this code type when it runs.
Code 39 If True, the tool looks for this code type when it runs.
Code 39 Full ASCII If True, the tool looks for this code type and Code 39 when it runs. This
property is not set by Training. It must be set manually.
Code 32 If True, the tool looks for this code type when it runs. (This code type is
also included if Code 39 or Code 39 Full ASCII is enabled.)
Code 93 If True, the tool looks for this code type when it runs.
Code 128 If True, the tool looks for this code type when it runs.
GS1 128 If True, the tool looks for this code type when it runs.
GS1 Databar If True, the tool looks for this code type when it runs.
GS1 Databar
Stacked
If True, the tool looks for this code type when it runs.
GS1 Databar Lim-
ited
If True, the tool looks for this code type when it runs.
GS1 Databar
Expanded
If True, the tool looks for this code type when it runs.
GS1 Databar
Expanded Stacked
If True, the tool looks for this code type when it runs.
Interleaved 2 or 5 If True, the tool looks for this code type when it runs.
Standard 2 of 5 If True, the tool looks for this code type when it runs.
Input Name What it is