5. In the list of items, select Internet Protocol Version 4 (TCP/IPv4), then click Properties.
6. Select Use the following IP address.
7. Enter the desired IP address.
8. Click OK to close all the open dialog windows.
Changing the device or camera’s Mask and Address (A, T, and C-Series)
To change the device or camera’s IP Mask and Address, you must know the current IP Address and Mask so
you can configure the client correctly. The Datalogic Impact device or camera is shipped with a default IP
Address of 192.168.0.128 and a default Mask of 255.255.255.0.
IMPORTANT: If you change a device or camera’s Mask or Address, be sure to record the new values.
IMPORTANT: Do NOT include a leading zero in an IP Address group (for example 192.168.108.065)
1. Be sure that the client computers IP Address and Mask are set correctly. Connect the client computer
and device or camera’s Ethernet ports directly using an Ethernet cable (A, T, and C-Series only) and
turn on power to the device.
2. Connect to the desired device or camera. See “Connect to an Impact device, camera, or Emulator” on
page 1-5.
IMPORTANT NOTE: If you intend to change both the IP Address and the IP Mask, do not Reboot
until you have changed them both. After you change the IP Address, you will see a message that states
you must reboot for the changes to take effect. Do not reboot until after you have changed both the
Mask and the Address. On T4x-Series and A30 cameras, you need to cycle power for the changes to
take effect.