Hardware manual

Impact Reference Guide Angle
3-113 Datalogic Automation Inc.
the cursor changes as shown below, then click and drag.
These Wide Line ROIs are the same as those in the Line Find tool with the following settings: Grey
level edges, Automatic thresholding, Medium noise level, Sampling of 50%, and Outlier distance of
three pixels. If you want to use different settings, add a Line Find tool to the task and link that tool’s
Line Segment into the Angle tool.
2b. To link a Line Segment or Origin from another tool:
Select the type of ROI you want to link for Line 1 or Line 2: Link Line Segment or Link Origin.
Type the ROI coordinates into the Source field or click the Link button and link the desired Line Seg-
ment or Origin. If the Line is linked, the source is displayed.
3. Check the Rotate 180 Degrees check box if you want the Line to point in the opposite direction. Rota-
tion may not change the reported angle, depending on the Direction and Endpoint selections on the
Pass/Fail panel. The Found or Linked Lines are marked on the image.
4. Click the Pass/Fail radio button.
Rotate the
ROI
ROI positioned on image
Move the ROI
Adjust the ROI width
Line 1 First Dark
Line ROI and
Found Line
Line 2 Linked
Line Segment