Datasheet
www.datalogic.com www.datalogic.com
The Diffuse proximity model is available in two versions: a short
range version, able to detect opaque objects up to 300 mm and
a long range version with 500 mm operating distance. The high
ambient light immunity of these models allows to use the sensor
even in presence of fluorescent and strooboscopic lamps.
DIFFUSE PROXIMITY
max. operating distance
SHORT RANGE (S100-…-B0) LONG RANGE (S100-…-B1)
with R5 reflector with R2 reflector with R5 reflector with R2 reflector
NO SLIT
0,02 … 3,5 m 0,02 … 2,3 m 0,1...6,15 m 0,01...5,15 m
2 mm SLIT
0,05 … 1,7 m 0,05 … 1 m 0,2...4,4 m 0,03...3,5 m
1 mm SLIT
0,1 … 0,55 m 0,1 … 0,3 m 0,3...3 m 0,05...2,1 m
0,5 mm SLIT
not usable not usable 0,5...1,5 m 0,07...1 m
SHORT RANGE
(S100-…-C0)
LONG RANGE
(S100-…-C1)
Recommended operating distance
(on White 90% target)
10…240 mm 2…400 mm
Maximum operating distance
(White 90% target)
1...300 mm 0...500 mm
Maximum operating distance
(Grey 18% target)
20...150 mm 10...280 mm
Maximum operating distance
(Black 6% target)
30...80 mm 20...160 mm
Difference White-Grey 50% 50%
Difference White-Black 75% 75%
Hysteresis 20% 20%
-8
-6
-4
-2
0
2
4
6
8
0 50 100 150 200 250 300 350
Detection Area [mm]
Distance [mm]
Detection Area
Diffuse (short range: S100-C00)
WHITE 90%
GREY 18%
1
10
100
0 50 100 150 200 250 300 350
Excess Gain
Distance (mm)
Excess Gain
Diffuse (short range: S100-C10)
White 90% Grey 18%
1
10
100
0 50 100 150 200 250 300 350 400 450 500 550
Excess Gain
Distance (mm)
Excess Gain
Diffuse (long range: S100-C10)
White 90% Grey 18%
DIFFUSE (SHORT RANGE: S100-C00)
DIFFUSE (LONG RANGE: S100-C10)
-15
-10
-5
0
5
10
15
0 50 100 150 200 250 300 350 400 450 500 550
Detection Area [mm]
Distance [mm]
Detection Area
Diffuse (long range: S100-C10)
WHITE 90%
GREY 18%
Miniature Sensors - S100