Specifications
Table Of Contents
- Falcon® 4400 Series
- with Windows Mobile®
- Table of Contents
- How to Use this Manual
- Document Overview
- Registering Your Datalogic Product
- Document Conventions
- Batteries and Power
- Configuration Settings
- Software Programs
- Accessories
- Falcon® Desktop Utility
- SNMP Interface
- Cable & Connector Configurations
- Programming Parameters
- Overview
- Programming Codes Without Parameters
- Bar Code Parameters
- Codabar
- Code 39
- Code 93
- Code 128
- European Article Numbering-13 (EAN-13)
- European Article Numbering-8 (EAN-8)
- Interleaved 2 of 5
- Matrix 2 of 5
- MSI
- Pharmacode 39 (Code 32)
- RSS-14
- RSS Limited
- RSS Expanded
- Standard 2 of 5
- Trioptic
- Universal Product Code-A (UPC- A)
- Universal Product Code-E (UPC- E)
- UPC/EAN Extensions
- Aztec Code
- DataMatrix
- Composite
- Maxicode
- OCR
- PDF 417
- MicroPDF 417
- QR Code
- Imaging Controls
- Other Controls
- OCR Configuration
- Programming Bar Codes
- Overview
- Predefined Defaults
- Codabar
- Code 39
- Code 93
- Code 128
- EAN-13
- EAN-8
- Interleaved 2 of 5
- Matrix 2 of 5
- MSI
- Pharmacode 39 (Code 32)
- RSS-14
- RSS Limited
- RSS Expanded
- Standard 2 of 5
- Trioptic
- UPC-A
- UPC-E
- UPC/EAN Extensions
- 2D Symbologies
- Aztec Code
- DataMatrix
- Composite
- Maxicode
- OCR
- PDF-417
- MicroPDF-417
- QR Code
- Imager Labels
- Other Controls
- SDK Installation
- Glossary
- Index

Bar Code Parameters
Product Reference Guide E-35
Spotting Beam
Timeout
Sets the duration of the spotting beam
before it automatically turns off.
0
0
2
3
00 = 0.25 sec.
01 = 0.5 sec.
02 = 1.0 sec.
03 = 1.5 sec.
04 = 2.0 sec.
01 01 01
Release Scan
Timeout
Sets the duration of the scan before it
turns off.
0
0
2
4
1-10 02 02 02
Number of
Good-Read
Beeps
Determines the number of beeps for a
good read indicator.
0
0
2
0
01 - 04 01 01 01
Good-Read
Beep Tone
Adjusts the pitch of the beeper frequency.
0
0
2
1
00 - 07
(00 = Lowest;
07 = Highest)
00 00 00
Good-Read
Beep Duration
Determines the duration of a good read
beep.
0
0
2
2
00 = 0.07 sec.
01 = 0.13 sec.
02 = 0.18 sec.
03 = 0.36 sec.
00 00 00
Send Symbol-
ogy Identifiers
Specifies the symbology identifier (if any)
that is sent by the decoder when parame-
ter Send Code ID (Index 0025) is set to 3.
ASCII code zero (null) used to indicate
an identifier not to be sent for the symbol-
ogy.
0
0
2
5
00 = Off
01 = DLM
IDs*
02 = AIM IDs
03 = User IDs
00 01 00
Label Prefix
Indicates a label prefix.
0
0
2
6
Any single
ASCII charac-
ter
(00 = Off)
No
ne
Non
e
None
Code Parameter/ Description
I.
D.
#
Acceptable
Input
Defaults
Min Max Factory