Specifications
Table Of Contents
- Falcon® 4400 Series
- with Windows Mobile®
- Table of Contents
- How to Use this Manual
- Document Overview
- Registering Your Datalogic Product
- Document Conventions
- Batteries and Power
- Configuration Settings
- Software Programs
- Accessories
- Falcon® Desktop Utility
- SNMP Interface
- Cable & Connector Configurations
- Programming Parameters
- Overview
- Programming Codes Without Parameters
- Bar Code Parameters
- Codabar
- Code 39
- Code 93
- Code 128
- European Article Numbering-13 (EAN-13)
- European Article Numbering-8 (EAN-8)
- Interleaved 2 of 5
- Matrix 2 of 5
- MSI
- Pharmacode 39 (Code 32)
- RSS-14
- RSS Limited
- RSS Expanded
- Standard 2 of 5
- Trioptic
- Universal Product Code-A (UPC- A)
- Universal Product Code-E (UPC- E)
- UPC/EAN Extensions
- Aztec Code
- DataMatrix
- Composite
- Maxicode
- OCR
- PDF 417
- MicroPDF 417
- QR Code
- Imaging Controls
- Other Controls
- OCR Configuration
- Programming Bar Codes
- Overview
- Predefined Defaults
- Codabar
- Code 39
- Code 93
- Code 128
- EAN-13
- EAN-8
- Interleaved 2 of 5
- Matrix 2 of 5
- MSI
- Pharmacode 39 (Code 32)
- RSS-14
- RSS Limited
- RSS Expanded
- Standard 2 of 5
- Trioptic
- UPC-A
- UPC-E
- UPC/EAN Extensions
- 2D Symbologies
- Aztec Code
- DataMatrix
- Composite
- Maxicode
- OCR
- PDF-417
- MicroPDF-417
- QR Code
- Imager Labels
- Other Controls
- SDK Installation
- Glossary
- Index

Bar Code Parameters
Product Reference Guide E-21
User ID
Specifies the symbology identifier
(if any) that is sent when parameter
Send Code ID (Index 0025) is set to
3.
ASCII code zero (null) is used
to indicate that an identifier is not to
be sent for the symbology
0
1
2
5
Any
single
ASCII
charac-
ter
(00 =
Off)
'X' 'X' 'X'
99
Universal Product Code-A (UPC-
A)
Enter 1 for On
and 0 for Off.
Enable
Enables/disables the UPC-A sym-
bology.
0
5
0
0
On or
Off
Off On On
99
Enable
Aggres-
sive
Decoding
Enables more aggressive decoding
algorithms to be used in order to
scan hard to read labels.
0
5
0
1
On or
Off
Off On Off
9
Send
Check
Digit
Includes check digit in the label
which is transmitted.
0
5
0
2
On or
Off
Off On Off
99
Send Sys-
tem Digit
Includes the system digit in the
label transmission. For UPC-A, the
system digit is always zero.
0
5
0
3
On or
Off
Off On On
99
Convert
UPC-A to
EAN-13
Instructs the decoder to expand
UPC-A labels to their EAN-13
equivalents. Any EAN-13 parame-
ters will then apply to the result.
0
5
0
4
On or
Off
Off On Off
9
Code Parameter/ Description
I.
D.
#
Accep-
table
Input
Defaults Scanner Type
Min Max
Fac-
tory
Laser/
Linear
Imager
2D
Imag
er