Specifications
Table Of Contents
- Falcon® 4400 Series
- with Windows Mobile®
- Table of Contents
- How to Use this Manual
- Document Overview
- Registering Your Datalogic Product
- Document Conventions
- Batteries and Power
- Configuration Settings
- Software Programs
- Accessories
- Falcon® Desktop Utility
- SNMP Interface
- Cable & Connector Configurations
- Programming Parameters
- Overview
- Programming Codes Without Parameters
- Bar Code Parameters
- Codabar
- Code 39
- Code 93
- Code 128
- European Article Numbering-13 (EAN-13)
- European Article Numbering-8 (EAN-8)
- Interleaved 2 of 5
- Matrix 2 of 5
- MSI
- Pharmacode 39 (Code 32)
- RSS-14
- RSS Limited
- RSS Expanded
- Standard 2 of 5
- Trioptic
- Universal Product Code-A (UPC- A)
- Universal Product Code-E (UPC- E)
- UPC/EAN Extensions
- Aztec Code
- DataMatrix
- Composite
- Maxicode
- OCR
- PDF 417
- MicroPDF 417
- QR Code
- Imaging Controls
- Other Controls
- OCR Configuration
- Programming Bar Codes
- Overview
- Predefined Defaults
- Codabar
- Code 39
- Code 93
- Code 128
- EAN-13
- EAN-8
- Interleaved 2 of 5
- Matrix 2 of 5
- MSI
- Pharmacode 39 (Code 32)
- RSS-14
- RSS Limited
- RSS Expanded
- Standard 2 of 5
- Trioptic
- UPC-A
- UPC-E
- UPC/EAN Extensions
- 2D Symbologies
- Aztec Code
- DataMatrix
- Composite
- Maxicode
- OCR
- PDF-417
- MicroPDF-417
- QR Code
- Imager Labels
- Other Controls
- SDK Installation
- Glossary
- Index

Bar Code Parameters
Product Reference Guide E-15
MSI
Enter 1 for On
and 0 for Off.
Enable
Enables/disables the MSI symbol-
ogy.
0
6
0
8
On or
Off
Off On Off
99
Enable
Aggres-
sive
Decoding
Enables more aggressive decoding
algorithms to be used in order to
scan hard to read labels.
0
6
0
9
On or
Off
Off On Off
9
Require
2 Check
Digits
An MSCI label must contain 2
check digits.
0
6
0
A
On or
Off
Off Off Off
9
Send
Check Dig-
its
This instructs the decoder to
include any enabled check digit(s)
in the label which is transmitted.
0
6
0
B
On or
Off
Off On Off
99
2nd Check
Digit Mod
11
Instructs the decoder to interpret
any second MSI check digit as
modulo 11 instead of modulo 10.
0
6
0
C
On or
Off
Off Off Off
9
Minimum
Label
Length
Set the minimum label length to be
less than or equal to maximum
label length.
0
6
2
4
01 - 15 01 01 04
99
Maximum
Label
Length
This feature specifies the maximum
allowable length of an MSI label.
The length includes check and data
characters. Maximum Label Length
should be greater than or equal to
Minimum Label Length.
0
6
2
5
01 - 15 01 15 10
99
Code Parameter/ Description
I.
D.
#
Accep-
table
Input
Defaults Scanner Type
Min Max
Fac-
tory
Laser/
Linear
Imager
2D
Imag
er