Integration Guide

Technical Specifications
28
DE2011-DL
Power Consumption Details
While operating, the engine switches between different status conditions.
Each status is characterized by a specific power consumption level.
Assuming the system is at 23°C and all three power supplies are at 3.3V, the
typical current absorption is reported in the table below (engine parameters
set at factory default).
Table 8. Mean power consumption upper limits
<0.2mA
Temperature 23°C
Illumination lamp duration 600us
AIM laser-on duration 8500us
VDD = 3.3V
VDD_SENSOR = 3.3V
VDD_ILLUM = 3.3V
Idle 21mA
Image Acquisition 70mA
Illumination Enabled
lamp duration 600us - factory default
150mA
Illumination Enabled and AIM Enabled
factory default timing
160mA
Maximum Operating Current
AIM on at factory default and
lamp duration 1000us (maximum value)
200mA
Low power
The engine is in sleep (minimum power consumption)
Idle
The engine is active, waiting for commands and ready to start an
acquisition
Running
The engine is acquiring and streaming images to the host. Power
consumption depends on the configuration of the engine
DE2011 status
Current
Consumption
Conditions
Low power