Integration Guide

Software Interface
24
DE2011-DL
Table 7. User Custom Parameters ID codes and length
The following parameters are READABLE and WRITABLE.
Illumination
Duration
Customizable default/startup value for the illumi-
nation pulse time (per frame)
1 Byte
:
0x00-0x0C = illumination time se
t to value*50us.
0x00B7 1
600us
(0x0C)
Illumination
Delay
Customizable default/startup value for the delay
time from start of exposure to start of illumination
2 Bytes:
value in us
0x00B8 2
30us
(0x001E)
Aim Duration
Customizable default/startup value for the AIM pat-
tern “on” time (per frame)
2 Bytes:
value in us
0x00B9 2
8500us
(0x2134)
Aim Delay
Customizable default/startup value for the delay
time from end of exposure to start of AIM pattern
projection.
2 Bytes:
value in us
0x00B0 2
100us
(0x0064)
Max Exposure
Reg
Cus
tomizable default/startup value for the Aptina
MT9V024 Max ex
posure register, which determines
the maximum sensor exposure time per frame.
Each unit corresponds to one row time.
1 Byte
:
Register Address (0xAD)
+
2 Bytes:
Register Value
0x00B1 3
Address:
0xAD
Value:
0x00C0
EXAMPLE: Getting a Scan Engine Serial Number
Cmd Name = GET CAMERA PAR
Cmd_Code = 0x40
Parameter ID Code = 0x0001
Parameter Length = 16 bytes
SEND COMMAND to the ENGINE:
<write> 0x40 0x01 0x00 0xBF
The last byte 0xBF represents the checksum
GET RESPONSE from the ENGINE:
<read> 0x40 0x80 0x01 0x00 0x.. 0x.. 0x.. 0x.. 0x.. 0x.. 0x.. 0x.. 0x.. 0x.. 0x.. 0x.. 0x..
0x.. 0x.. 0x..
Tthe second byte 0x80 represents the status code that in this case
is ACK
The sixteen bytes 0x.. represent the serial number of the engine
Parameter Description
ID
Code
Length
(Bytes)
FACTORY