Integration Guide

Software Interface
22
DE2011-DL
[0x3C] SENSOR
BINNING
Sets the binning
operated by the Sensor.
1 Byte:
0x00=Normal
Row binning codes:
0x00 = No Row Bin
0x01 = Row Bin 2
0x02 = Row Bin 4
Column Binning
codes:
0x00 = No Column
Bin
0 x04 = Column Bin 2
0x08 = Column Bin 4
Resulting Parameter
for Image Binning =
(Row binning code) +
(Column Binning
code)
Cmd
Code
Cmd Name Description Parameters
Response Data
(if present)
See
Table 6 on page 23
and
Table 7 on page 24
for details
on parameter length and ID code.