Table 3. Engine connector description
GND power Ground
2 GND power Ground
3 I2C_CLK I I2C Clock
4 I2C_DATA I/O I2C Data
5 V_SYNC O Vertical sync
6 PIX_DATA_7 O Video data bus, pixel 7 – MSB
7 PIX_DATA_6 O Video data bus, pixel 6
8 PIX_DATA_5 O Video data bus, pixel 5
9 PIX_DATA_4 O Video data bus, pixel 4
10 PIX_DATA_3 O Video data bus, pixel 3
11 PIX_DATA_2 O Video data bus, pixel 2
12 PIX_DATA_1 O Video data bus, pixel 1
13 PIX_DATA_0 O Video data bus, pixel 0 – LSB
14 FLASH_OUT O External illumination system trigger
15 VDD_SENSOR power Sensor power supply
16 VDD power Digital power supply
17 VDD_ILLUM_SYS power Illumination system power supply
18 H_SYNC O Horizontal sync
19 GND power Ground
20 PIX_CLK O Sensor pixel clock
21 GND power Ground
Connector and Flat cable
The DE2011-DL scan engine is equipped with a Kyocera 21-pole ZIF con-
nector having a pitch of 0.3mm – series 6283 - ordering code 04 6283 021
00
2 868.
For further details and requirements related to the flat
cable, please refer to
the manufacturer’s datasheet, available at
http://www.kyocera‐connec‐
tor.com/prdct/type/fpc/index.html#2
Powerup sequence
In order to guarantee the correct operation of the engine, it is mandatory to
use the following powerup sequence timing constraints:
• VDD_SENSOR must be stable at 3.3V not late
r than 6ms after the VDD is
at 2.1V.
• VDD_ILLUM_SYS
must be stable at 3.3V at least 20ms before issuing
any camera start command.
Engine latency at powerup
At powerup the engine begins executing the code when the power supply
level reaches 2.1V. To complete the boot sequence, a 12ms time is required.
After this, the engine is ready to parse commands.