User manual
READING FEATURES
4
1. Place the code at the desired position on the scan line (i.e. Position 1)
2. Measure the X, Y and Z coordinates relative to the center of the code and enter them into
the corresponding edit boxes.
3. Press the Calibrate button for Position 1 to start the calibration.
4. Repeat the same procedure for Position 2 and Position 3.
5. Press the “Validate Calibration” button to validate the calibration settings.
Before closing the dialog box, press the Run Test button to test the calibration results and
efficiency.
NOTE
In the vast majority of systems the x and z data are not necessary. For
these cases set x = 0, z= 0 during the calibration procedure.
4.3.2 PackTrack™ Calibration for DS6500 Oscillating Mirror Models
The DS6500 oscillating mirror models can be used in PackTrack™ operating mode only
when the scanner is mounted so that the
scan line is parallel to the conveyor direction as
shown in the following figure:
Conveyor
Direction
Scan
Line
Figure 79 – Oscillating Mirror Models in PackTrack™ Mode
PackTrack™ Calibration must be made while the
scanning plane is perpendicular to the
conveyor plane and fixed (not oscillating).
67