4.3 PACKTRACK™
PackTrack™ is a patented operating mode for Datalogic Omni-Directional Reading Stations
used to read and correctly assign codes read on different packs when placed in the scanner
Reading Area at the same time.
In fact, in the following example, the codes of two or more consecutive packs are found at
the same time in the scanner reading area. Therefore, the condition occurs where, in the
sequence of the two packs, the code of the second pack is read first, just before the code of
the previous pack. A system without PackTrack™ would assign the code of the second pack
to first pack and vice versa, thus causing a gross error in sortation.
Figure 74 – PackTrack™ System Layout
Working in PackTrack™ mode requires the presence of an encoder and a presence sensor
to track the moving packs.
All PackTrack™ functionalities are programmed via the Genius™ tool (refer to the Genius™
Help On-Line for details).
For correct functioning, the PackTrack™ operating mode requires a calibration just after the
installation of the scanners. This operation is absolutely necessary to make the scanner
recognize its position in space. Thus, a fixed reference system is required.
PackTrack™ uses a right-handed reference system (right hand with thumb = X axis;
forefinger = Y axis; middle finger = Z axis) where the axis X coincides with the PS line, the Y
axis coincides with the conveyor direction and the Z axis is oriented upwards from the
conveyor (see figure below).
This coordinate system is absolute for the reading station, i.e. is valid for all the scanners
independently from their position or orientation with respect to the conveyor.
64