2.7.4 Multiplexer
The Multiplexer connection is used to integrate a DS6500
slave reader in a Multidrop
network consisting of different scanners not provided with a Lonworks interface.
Each scanner is connected to a Multiplexer (MX4000) with the RS485
half-duplex main interface.
E
N
T
<
<
E
N
T
<
<
P.S.*
P.S.*
P.S.*
DS4600
A
DS4600
A
DS6500
PWR-120
CAB-600X
C
C
C -BOX 100
-BOX 100
-BOX 100
MX4000
1
#0
#31 #1
Local Host
1
RS485 HD Main Interface
* P.S. (Presence Sensor) connected to External Trigger/PS input.
Figure 55 – Multiplexer for DS6500 Master/Slave Models
The auxiliary serial interface of the slave scanners can be used to visualize collected data or
to configure it using the Genius™ utility.
When On-Line operating mode is used, the scanner is activated by an External Trigger when
the object enters its reading zone.