User manual

INSTALLATION
2
2.6.2 “45° Skew” Installation
The DS6500 scanner is mounted on the ST-210 90° mounting bracket (see Figure 11). By
adjusting the mounting bracket guides, reach 45° for the Skew angle (S in the figure below)
to avoid the direct reflection of the laser light emitted by the scanner:
S
45º
Figure 48 – 45° Skew Installation
ATTENTION
If using the “45° Skew” installation, it is not guaranteed that the scanner
reading performance (see reading diagrams in par. 4.5.1) will match that
measured for the standard installation with Skew angle between
10° - 20°.
NOTE
The ST-210 mounting bracket is an accessory of the DS6500 standard
model available in the US-60 kit (890001020).
2.7 TYPICAL LAYOUTS
The DS6500 scanners can be connected in a variety of layouts depending on the number of
scanners used and the required complexity of the reading station. These layouts range from
Single Stand Alone to Complex Lonworks Networks.
Several power supplies are available to power the reading stations. Photoelectric sensors
used as code presence sensors and optical encoders to signal conveyor speed are also
available accessories.
The following typical layouts refer to the system hardware configurations, but they also
require the correct setup of the software configuration parameters (see par. 3.2 for details).
The accessories and cables indicated in the following figures are Datalogic products. We
suggest their use to guarantee the correct system functioning.