Network Device User's Manual

RHINO-NET™
1
1.8 BLUETOOTH® MODULE
Rhino-NET™/RF-3 EU BT Low Temp model is equipped with a Bluetooth® module for radio
communications to other devices which use this standard, for example a Gryphon BT
scanner, printers, etc.
Connections are not guaranteed at temperatures below 0° C.
1.9 CONNECTORS
All external connectors for Rhino-NET™ are located on the bottom of the unit.
The COM 1 port connects any EIA RS232 device. It also can be wired to connect a scanner
powered by an external power source.
The COM 2/Scanner port has been designed to connect and power a scanner with 5V power
supply on pin 9. This port can also be used to connect RS232 devices that are not influenced
by the 5V provided on pin 9 of the COM2/Scanner connector.
The maximum current draw allowed is 0.5 A @ 5 VDC; therefore, do not attach scanners or
other devices that exceed this value.
The following tables illustrate the pinout for COM1 and COM2/Scanner ports respectively:
COM1
Pin Function Type
1 DCD Input
2
RX Input
3
TX Output
4
DTR Output
5
GND Ground
6
DSR Input
7
RTS Output
8
CTS Input
9
RIN Input
COM2/Scanner
Pin Function Type
1 DCD Input
2
RX Input
3
TX Output
4
DTR Output
5
GND Ground
6
DSR Input
7
RTS Output
8
CTS Input
9
+5V Supply voltage
4