User manual
Bar Code Parameters
Product Reference Guide
F-7
Send Check
Digit
Instructs the terminal to include the check digit
in the label transmission.
051A On / Off Off On Off
Convert EAN-
8 to EAN-13
Instructs the decoder to expand EAN-8 labels
to their EAN-13 equivalents. Any EAN-13
parameters will then apply to the result.
051B On / Off Off On Off
Read Verifi-
cation
Sets the number of times a label must be read
before it is transmitted.
0526 01 - 04 01 02 01
User ID
Specifies the symbology identifier (if any) that
is sent by the decoder when parameter Send
Code ID (Index 0025) is set to 3. "ASCII" code
zero (null) is used to indicate that an identifier
is not
to be sent for the symbology.
0527
Any single
ASCII
ch
aracter
(00 = Off)
'G' 'G'
'G'
Interleaved 2 of 5
Enter 1 for On
and 0 for Off.
Enable
Enables/disables the Interleaved 2 of 5 sym-
bology.
0210 On / Off Off On On
Enable
Aggressive
Decoding
Enables more aggressive decoding algorithms
to be used in order to scan hard to read
labels.
0211 On / Off Off On Off
Enable
Checksum
Requires the use of checksum characters to
verify a bar code.
0212 On / Off Off Off Off
Send Check-
sum
Instructs the terminal to include the checksum
in the label transmission.
0213 On / Off Off Off Off
Enable Case
Code
Restricts Interleaved 2 of 5 label lengths to
only 6 and 14 data characters. Enabling this
parameter overrides the minimum and maxi-
mum length values.
0214 On / Off Off Off Off
Minimum
Label Length
Set the minimum label length to be less than
or equal to maximum label length.
0228 02 - 50 02 02 06
Maximum
Label Length
This feature specifies the maximum allowable
length of a Interleaved 2 of 5 label. The length
includes check and data characters. Maximum
Label Length should be greater than or equal
to Minimum Label Length.
0229 02 - 50 02 50 10
Read Verifi-
cation
Sets the number of times a label must be read
before it is transmitted.
022A 01 - 04 01 02
01
Code Parameter/ Description I.D. #
Acceptable
Input
Defaults
Min Max Factory