Matrix-1000™ QUICK REFERENCE GUIDE 2 3 4 5 6 7 8 9 10 1 Matrix-1000™ – GENERAL VIEW 1 2 3 4 Reading Window F2 LED Keypad button F1 LED NOTE 5 6 Power On LED External Trigger LED 7 8 Good Read LED Communication LED 9 Main/Auxiliary Interface 10 Auxiliary Interface This manual illustrates a Stand Alone application. For Multiplexer Layouts and for a complete reader configuration using VisiSet™ configuration program, refer to the Matrix-1000™ Reference Manual available on the CD.
MATRIX-1000™ QUICK GUIDE STEP 1 – CONNECT THE SYSTEM To connect the system in a Stand Alone configuration, you need the hardware indicated in Figure 1. In this layout the data is transmitted to the Host on the RS232 auxiliary serial interface which is also used for reader configuration by running VisiSet™. When One Shot or Phase Mode Operating mode is used, the reader is activated by an External Trigger (photoelectric sensor) when the object enters its reading zone. CAB-600X CBOX-100 Matrix-1000™ P.S.
MATRIX-1000™ QUICK GUIDE STEP 2 – MOUNTING AND POSITIONING THE SYSTEM 1. To mount the Matrix-1000™, use the mounting bracket to obtain the most suitable position for the reader as shown in the figures below. Figure 2 - Positioning with Mounting Bracket 2. When mounting the Matrix-1000™ take into consideration these three ideal label position angles: Pitch or Skew 10° to 20° and Tilt 0°, although the reader can read a code at any Tilt angle.
MATRIX-1000™ QUICK GUIDE STEP 3 – AUTO-LEARNING CONFIGURATION An autolearning procedure is available to reduce installation time.
MATRIX-1000™ QUICK GUIDE If your application has been configured using Auto Learn, your reader is ready. If necessary you can use VisiSet™ for advanced reader configuration. NOTE POSITIONING (OPTIONAL) At the end of the Auto Learn procedure, you can use the Positioning procedure to center the code with respect to the reader's FOV. 1.
MATRIX-1000™ QUICK GUIDE STEP 4 – INSTALLING VISISET™ CONFIGURATION PROGRAM VisiSet™ is a Datalogic reader configuration tool providing several important advantages: • Autolearning Wizard for new users; • Defined configuration directly stored in the reader; • Communication protocol independent from the physical interface allowing to consider the reader as a remote object to be configured and monitored.
MATRIX-1000™ QUICK GUIDE The Autolearning Wizard option is advised for rapid configuration or for new users. It allows reader configuration in a few easy steps. 1. Select the Autolearning Wizard button from the Main menu. 2. Place the desired code in front of the reader at the correct reading distance (depending on the model, see the Reading Features table in the Appendix of this Quick Reference Guide). 3. Press the "Positioning" button.
MATRIX-1000™ QUICK GUIDE 5. If the code symbology is not enabled by default, select a Code Setting Mode choice and press the "Code Setting" button. The Autolearning Result section of the Autolearning Wizard window shows the parameter settings and the code type results. 6. Select a Saving Options choice and press the "Save" button. 7. Close the AutoLearning Wizard. If your application has been configured using the VisiSet™ Autolearning Wizard, your reader is ready.
MATRIX-1000™ QUICK GUIDE ADVANCED READER CONFIGURATION For further details on advanced product configuration, refer to the complete Reference Manual on the installation CD-ROM or downloadable from the web site through this link: www.automation.datalogic.com/matrix1000.
MATRIX-1000™ QUICK GUIDE APPENDIX READING FEATURES READING FEATURES Frame Rate Up to 30 frames/sec. with VGA images Readable Codes per Frame Pitch Tilt Up to 100 10° - 35° 0° - 360° (3) 1021 HD 115 (4.53) 25 × 19 (0.98 × 0.75) 653 Typ. Linear and Stacked Code Resolution mm (mils) 0.10 (4) 1031 SD 155 (6.10) 34 × 26 (1.34 × 1.02) 478 0.15 (6) 0.25 (10) 135 (5.31) 180 (7.08) 1041 LD 110 (4.33) 300 0.20 (8) 0.38 (15) 90 (3.45) 140 (5.51) 1051 MR 210 (8.26) 170 0.30 (12) 0.
MATRIX-1000™ QUICK GUIDE TECHNICAL FEATURES ELECTRICAL FEATURES Power Supply Voltage Power Consumption Communication Interfaces Main - RS485 half-duplex Auxiliary - RS232 Input External Trigger Outputs OUT3 10 to 30 Vdc 4 W max.; 2.5 W typical 2400 to 115200 bit/s 2400 to 115200 bit/s Opto-coupled and polarity insensitive Opto-coupled OPTICAL FEATURES Image Sensor Image Format Lighting System Wavelength Max LED Output Power LED Safety Class Matrix CCD VGA (640x480) LED array 630 ~ 670 nm 0.
MATRIX-1000™ QUICK GUIDE MECHANICAL DIMENSIONS 57 [2.24] = mm [inch] M4 x 5 n°4 121 [4.76] 57 [2.24] 28.1 [1.11] = 73 [2.87] 57 [2.24] 18.1 [0.71] 57 [2.24] 4 [0.16] M4 x 5 n°4 Figure 10 – Matrix-1000™ Overall Dimensions 73 [2.87] 95 [3.74] .2 Ø 4 17] . [Ø0 37 [1.46] 15 [0.59] 47.5 [1.87] 2 [0.08] 47.5 [1.87] 95 [3.74] 2 8. ] Ø .3 2 0 [Ø 4.2 [0.
MATRIX-1000™ QUICK GUIDE PATENTS This product is covered by one or more of the following patents: U.S. patent: 6,512,218 B1; 6,616,039 B1 European patent: 999,514 B1; 1,014,292 B1. SERVICES AND SUPPORT Datalogic provides several services as well as technical support through its website. Log on to www.automation.datalogic.
DECLARATION OF CONFORMITY 07 Datalogic Automation S.r.l. Via S.