DS4800 QUICK REFERENCE GUIDE 4 3 2 1 5 6 Figure A NOTE 1 "POWER ON" LED 4 Display 2 Focus Adjustment 5 Laser Beam Output Window 3 Indicator LEDs 6 Push Button This manual illustrates a Stand Alone application. For other types of installations, such as ID-NET™, Pass-Through, Multiplexer Layout, etc. and for a complete scanner configuration using Genius™ configuration program, refer to the DS4800 Reference Manual available on the CD. This manual is also downloadable from the Web at www.
DS4800 QUICK GUIDE UPDATES AND LANGUAGE AVAILABILITY UK/US The latest drivers and documentation updates for this product are available on Internet. Log on to: www.automation.datalogic.com I Su Internet sono disponibili le versioni aggiornate di driver e documentazione di questo prodotto. Questo manuale è disponibile anche nella versione italiana. Collegarsi a: www.automation.datalogic.com F Les versions mises à jour de drivers et documentation de ce produit sont disponibles sur Internet.
DS4800 QUICK GUIDE STEP 1 – CONNECT THE SYSTEM To connect the system in a Stand Alone configuration, you need the hardware indicated in Figure 1. In this layout the data is transmitted to the Host on the main serial interface. In Local Echo communication mode, the RS232 auxiliary interface can be used to transmit data independently from the main interface selection.
DS4800 QUICK GUIDE 25-pin Connector Pinout for DS4800 The table below gives the pinout of the 25-pin male D-sub connector for connection to the power supply and input/output signals.
DS4800 QUICK GUIDE STEP 2 – MOUNT AND POSITION THE SCANNER 1. To mount the DS4800, use the mounting bracket to obtain the most suitable position for the reader as shown in the figures below. Skew Pitch -45° -15° 0° 15° 45° Figure 3 - Positioning with Mounting Bracket 2. When mounting the DS4800 take into consideration these three ideal label position angles: Skew 15° to 30°, Tilt 0° and Pitch 0°. P T S Assure at least 15° Minimize Minimize Figure 4 –Skew, Tilt and Pitch Angles 3.
DS4800 QUICK GUIDE STEP 3 – FOCUS THE SCANNER The reading distance depends on the focus distance of the scanner and should be set according to the application requirements. The Focus Position is set directly through the focus adjustment screw on the front panel of the scanner. This screw moves the internal lens of the scanner to change the focal length of the scanner.
DS4800 QUICK GUIDE STEP 4 – X-PRESS™ CONFIGURATION X-PRESS™ is the intuitive Human Machine Interface designed to improve ease of installation and maintenance.
DS4800 QUICK GUIDE AUTO SETUP (OPTIONAL) At the end of the Auto Learn procedure, you can perform the Auto Setup procedure to set up the reading parameters. 1. Enter the Auto Setup function by holding the X-PRESS™ push button pressed until the SETUP LED is on. 2. Release the button to enter the Auto Setup function. Once entered, if a barcode label is positioned in front of the scanline, the scanner automatically performs the optimal setup of the reading parameters for that specific barcode.
DS4800 QUICK GUIDE STEP 5 – INSTALL GENIUS™ CONFIGURATION PROGRAM Genius™ is a Datalogic scanner configuration tool providing several important advantages: • Wizard approach for new users; • Multi-language version; • Defined configuration directly stored in the reader; • Communication protocol independent from the physical interface allowing to consider the reader as a remote object to be configured and monitored.
DS4800 QUICK GUIDE a. Barcode selection and definition b. Operating mode selection and definition c. Digital Outputs configuration d. Hardware interface selection e. Output data format configuration The On Line operating Mode requires the reader to be connected to an External Trigger/Presence Sensor using I1A and I1B inputs. The Automatic operating mode does not require connection to an external Presence Sensor.
DS4800 QUICK GUIDE 2. After defining the parameter values the following window appears allowing to complete the reader configuration as follows: • Saving the configuration to disk; • Switching to Advanced mode; • Sending the configuration to the scanner. 3. After sending the configuration to the scanner you have completed the configuration process. 4. By clicking Finish, the System Information window will be displayed with specific information concerning the scanner.
DS4800 QUICK GUIDE STEP 6 – TEST MODE Use a code suitable to your application to test the system. Alternatively, you can use the Datalogic Test Chart (Code 128). 1. Enter the Test mode function by holding the X-PRESS™ push button pressed until the TEST LED is on. 2. Release the button to enter the Test mode function. Once entered, the Bar-Graph on the five LEDs is activated and if the scanner starts reading barcodes the Bar-Graph shows the Good Read Rate.
DS4800 QUICK GUIDE ADVANCED SCANNER CONFIGURATION For further details on advanced product configuration, refer to the complete Reference Manual on the installation CD-ROM or downloadable from the web site through this link: www.automation.datalogic.com/ds4800. The following are alternative or advanced scanner configuration methods: HOST MODE PROGRAMMING The scanner can also be configured from a host computer using the Host Mode programming procedure, by commands via the serial interface.
DS4800 QUICK GUIDE APPENDIX READING DIAGRAMS DS4800-1000 Focus Distance 30 cm (Near) 0 0 CONDITIONS Code = Code 128 PCS = 0.90 Pitch angle = 0° Skew angle = 15° Tilt angle = 0° *Scan Speed = 800 scans/sec *Reading Conditions = Standard *Reading Mode = Linear * Parameter selectable in Genius™ 20 50 15 40 5 10 10 20 30 15 20 40 50 30 25 60 ≥ 0.50 mm (20 mils) 10 20 5 0 5 10 0 10 20 10 30 15 40 20 50 (cm) (in) 14 0.20 mm (8 mils) 0.30 mm (12 mils) 0.
DS4800 QUICK GUIDE DS4800-1000 Focus Distance 40 cm (Medium) 0 0 CONDITIONS Code = Code 128 PCS = 0.90 Pitch angle = 0° Skew angle = 15° Tilt angle = 0° *Scan Speed = 800 scans/sec *Reading Conditions = Standard *Reading Mode = Linear * Parameter selectable in Genius™ 20 50 15 40 5 10 10 20 30 15 20 40 50 25 60 30 70 30 80 35 40 (in) 90 100 (cm) ≥ 0.50 mm (20 mils) 10 20 5 0 5 10 0 10 20 10 30 15 40 20 50 (cm) (in) 0.30 mm (12 mils) 0.
DS4800 QUICK GUIDE READING PERFORMANCE Version F = 30 F = 40 F = 60 Reading Distance 20 cm (7.9 in) - 47 cm (18.5 in) on 0.50 mm (20 mils) codes 25 cm (9.8 in) - 68 cm (26.8 in) on 0.50 mm (20 mils) codes 40 cm (16.7 in) - 100 cm (39.4 in) on 0.50 mm (20 mils) codes Max Code Resolution mm (mils) 0.20 (8) 0.30 (12) 0.38 (15) Speed scans/s 800 800 800 TECHNICAL FEATURES ELECTRICAL FEATURES Power Supply Max.
DS4800 QUICK GUIDE M5 13 [0.51] 42 [1.65] 10 [0.39] MECHANICAL INSTALLATION M5 M5 7.5 [0.30] 10 [0.39] mm [in] 41.4 [1.63] 27.9 [1.10] 87.7 [3.45] 5.2 [0.21] 37.8 [1.49] 34 [1.34] M4 37 [1.46] 41.9 [1.65] 85 [3.34] M4 M4 M4 101 [3.98] 81 [3.19] 12.1 [0.48] Figure 11 – DS4800 Overall Dimensions 3 [0.12] Ø4.2 4.2 [Ø0.17] N°4 [0.17] 10 [0.39] 120 [4.72] 4.2 [0.17] 30° 70 [2.76] Ø8.1 [Ø0.32] N°2 mm [in] 55 [2.17] 8.1 [0.32] N°8 Ø4.2 [Ø0.17] N°4 = 70 [2.76] = 80 [3.
DS4800 QUICK GUIDE PATENTS This product is covered by one or more of the following patents: U.S. patents 5,992,740; 6,394,352 B1; 6,742,710 B2; 6,688,524 B1 European patents 789,315 B1; 959,426 B9 Additional patents pending. COMPLIANCE LASER SAFETY The scanner is classified as a Class 2 laser product according to EN 60825-1 regulations and as a Class II laser product according to CDRH regulations.