Magellan 1100i OEM TM Presentation Omnidirectional Bar Code Reader Integration Manual
Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”).
Table of Contents Overview ........................................................................................................................... 1-1 Resources in other documents .............................................................................................. 1-1 Unpacking the Scanner ........................................................................................................ 1-2 Scanner Care .................................................................................
NOTES i-2 Magellan® 1100i OEM
Section 1 Introduction This document gives instruction, mechanical details, and design considerations to inte grate the Magellan 1100i OEM model (designated as “scanner” or “OEM scanner” in this manual) specifically into equipment-integrated scanning applications.
Introduction Unpacking the Scanner The scanner is shipped in custom packaging. Carefully open the package, and inspect for the following: • scanner • power supply (if ordered) • interface cable (if ordered) If any parts are damaged or you need additional hardware, please contact Technical Support. Scanner Care The scanner contains sensitive components which require special handling. Datalogic may not warrant damage due to improper handling. • Do not open the scanner's case.
Section 2 Mounting the Scanner This section describes how to design the mounting for optimum scanner performance. General Considerations A typical system uses the scanner mounted inside a host enclosure, with an opening for the scanning pattern to exit and read bar codes. The opening should be the size of the scanner window at a minimum, but only exposing as much of the scanner as necessary.
Mounting the Scanner Cable Routing The mounting design should also take into consideration the clearances needed for the interface cable. This cable should be routed internal to the host enclosure as much as possible. It is recommended to use a flat cable or round cable without a large strain relief so that the cable can be routed away from the scanner in one of the following directions. As shown in Figure 2-1, the interface cable can be routed out the rear or bottom sur faces of the scanner. Figure 2-1.
Design of the Scanner Opening Second, the scanner must be positioned so that the scan volume and illumination light will cover the entire bar code. The scan volume is shown in Figure 2-2. The combina tion of the Scan Volume and the illumination light is called the Field of View. Design ing around the scanner Field of View is explained more in the following section, Design of the Scanner Opening. Figure 2-2. Scanning Volume 147mm [5.79"] 94mm [3.70"] 13mm [0.5"] Scan Volume @ 165mm [6.
Mounting the Scanner Integrating the Scanner Behind a Window CAUTION It is not recommended to place any type of additional window between the scanner and the bar code to be read. The addition of a host enclosure window will significantly degrade scanner performance. This is due to the additional optical reflective surfaces that will cause interference with the imaging technology.
Appendix A Technical Specifications Optical and Read Performance Parameters Parameter Specification Scan Volume 1147 cm3 / 70 in3 Scan Pattern 136 scan lines Scan Rate 1760 Digital Scan Lines/second Minimum Resolution Depth of Field (100% UPC Labels) 5 mil Code Size Depth of Field 5 mil 25.4 - 57.2mm / 1.0 - 2.25” 7.5 mil 12.7 - 69.9mm / 0.5 - 2.75” 10 mil 12.7 - 139.7mm / 0.5 - 5.5” 13 mil 12.7 - 165.1mm / 0.5 - 6.5” 20 mil 12.7 - 184.2mm / 0.5 - 7.
Technical Specifications Environmental Parameters Parameter Specification Mechanical Shock Multi 1.0m drops Contaminants Water and Dust IP52 Temperature Ranges: Operating Storage Ambient Light Indoor Ambient Light Outdoor Humidity Beeper/Speaker Vibration 32 F to +122 F (0 C to +50 C) -104 F to +158 F (-40 C to + 70C) 0 - 6000 lux 0 - 86,100 lux 5 to 95% non-condensing 70-85dBA at a distance of 3’-3” (1 meter) Retail/Office Sine: 3.0 g pk, 5 Hz to 500 Hz Random: 0.
Appendix B Mechanical Specifications Physical Properties Parameter Dimensions Weight Specification 86.4 mm x 71.1 mm x 66.0 mm ( 3.4” x 2.8” x 2.6”) ~ 198 g / 7.0 oz.
Mechanical Specifications Clearance Required for Integration B-2 Magellan® 1100i OEM
Australia Japan Datalogic Scanning Pty Ltd Telephone: [61] (2) 9870 3200 australia.scanning@datalogic.com Datalogic Scanning KK Telephone: 81 (0)3 3491 6761 japan.scanning@datalogic.com France and Benelux Latin America Datalogic Scanning SAS Telephone: [33].01.64.86.71.00 france.scanning@datalogic.com Datalogic Scanning, Inc Telephone: (305) 591-3222 latinamerica.scanning@datalogic.com Germany Singapore Datalogic Scanning GmbH Telephone: 49 (0) 61 51/93 58-0 germany.scanning@datalogic.