User Manual
Table Of Contents
- Introduction
- Quick Start Instructions
- Using the PowerScan RF System
- Mounting the Base Station
- RF Programmable Features
- Programming Overview
- What Is Programming Mode?
- The Programming Session
- Programming Sequence
- Scanner vs. Base Station Features
- Interface (I/F) Selection
- Universal Keyboard Wedge I/F Selection
- Terminal/ Keyboard Settings
- RF Beeper Settings
- RF When to Beep
- RF When to Beep Options (continued)
- Radio Transmit Power
- RF Channel Selection
- Transmission Retries Before Message Time- out
- Wait Time for ACK
- Wait Time For Scanner Power Shutdown
- Wait Time Between Retries of Failed Transmission
- HACK Transmit Options
- Wait Time For HACK From Host
- Drop Links on Reset Option
- Drop Oldest Links Option
- Common Configuration
- Set Maximum Linked Scanners
- Source-Radio Identification (ID)
- Low Battery LED Indication
- Maintenance and Troubleshooting
- Standard Warranty
- Sample Bar Codes
- Number Pad
62 PowerScan™ RF Scanner
Wait Time For
HACK From
Host
This setting specifies the time the scanner must wait to receive a HACK
message back from the host before giving up and registering a trans-
mission error. Selectable range for this wait time is 20ms to 5.1 seconds
in 20ms increments. It is recommended that this value be set at no less
than one second.
Feature is specific to scanner ONLY
NOTE
Host turnaround (ACK) time is variable. This item
(HACK) should be set based on settings for the fea-
tures Wait Time for ACK and Transmission Retries
Before Message Time-out. For example if ACK is set
to one second and retries are set to three, HACK
should be set at three seconds.
SET -------------------------------------------
Set Wait Time For
HACK ---------
Scan three digits representing the desired delay using the Num-
ber Pad in Appendix B. Be sure the number is padded with lead-
ing zeros (example: 001 = 20ms, 100 = 1 second, 255 = 5.1
seconds, etc.), then scan the END bar code.
END ------------------------------------------