Configuration Commands
Title CFG FREQ
Summary
Sets three values used in deciding timing details of tests.
Tx/Rx Int (txrx_freq) sets the period in microseconds
between TX and RX events in RXDATA, TXDATA, BIT ERR and
LOOP BACK test modes. Default is 1250 (20 slots), maximum
65536. If passed as 0, current value unchanged.
Loopback (lb_offs) sets the offset in microseconds
between a reception event and retransmission of the data in
loopback. Default is 1875 (two slots later), must be less than
TX/Rx Int (txrx_freq). If passed as zero current value
unchanged.
Report Int(report_freqs) sets the time in seconds between
reports to host sent by RXDATA and BIT ERR functions. Default
1, if passed as 0 current value unchanged.
Related Test
Spec Name
None
Test Arguments
TX/RX Int (µS) = 1 to 65535 (default = 1250)
Loopback (µS) = 1 to 65535 (default = 1875)
Report Int (S) = 1 to 65535 (default = 1)
Return Data None.
Exit Click on Reset Chip.
CFG FREQ Example Display