Quantitative Tests
Transmitter Only
Title TXDATA1
Summary
Enables the transmitter, with a designated frequency
(LO Freq) and output Power
(Ext, Int)
.
Payload is PRBS9 data.
Receiver is not operating.
Packet type and duty cycle can be configured. Refer to Configuration Commands
section.
Related Test
Spec Name
TRM/CA/03/C (power control), TRM/CA/04/C (Tx output spectrum – frequency
range), TRM/CA/05/C (Tx output spectrum – 20dB bandwidth), TRM/CA/06/C
(Adjacent channel power), TRM/CA/08/C (Initial carrier frequency tolerance),
TRC/CA/01/C (Out-of-band spurious emissions).
Test Arguments
LO Freq (Carrier Frequency MHz)= 2402 to 2480
Power (Ext, Int) = gain of external amplifier (if present) and internal amplifier. Ext
value is specific to the design and Int value is 0 to 63 (Default = 50).
Return Data
None
Use an RF Analyser to check carrier output.
Exit Click on Reset Chip or select another TXDATA command.
TXDATA1 Example Display
BlueCore
TM
01
Quantitative Tests
Transmitter Only
Note: TXDATA and RXDATA require the
same Bluetooth address in each module
for
RXDATA to receive data transmitted
by
TXDATA. Use CFG_UAP_LAP to set
the address used by the BIST.