14.0 Firmware Updates
The i50 firmware can be updated by connecting a programming cable to the RJ-45 Prog connector
on the front panel, and using the Rabbit Field Utility (RFU) program. Programming cables may be
purchased from Datalink Systems, or made up using the pin outs defined in section 4.3. The RFU
program is available at http://www.datalinksystemsinc.com/download.html. Figure 9 shows the
program’s main screen.
Figure 9 Rabbit Field Utility
Use the Setup menu to access the File locations screen, as shown in Figure 10. Ensure the locations
point to the files supplied with the RFU program.
Figure 10 RFU file locations
Use the Setup menu to access the communications options. Select the options as shown in Figure
11, replacing the Serial Port setting with the correct port. Uncheck the Enable Processor Verification
option if you have problems connecting, and check the Use USB to Serial Converter option if
appropriate. If problems persist, try setting the Stop Bits to 1.