The integrated web server loads a web page and a Java Applet. The activity indicator
will be visible until the applet is loaded and running. Once the applet is fully loaded, a
password dialog window will appear. The default password is paradise. This password
may be changed in the Settings section of the web interface, and may comprise up to
15 alpha-numeric characters.
To select another password, enter the following selection on the RCP2 front panel:
Press the Main Menu key; select 2.Com.Setup and press the Enter key; select
3.IPNet and press the Enter key; select 5.IPConfig and press the Enter key; select
6.More and press the Enter key; select 4.WebPassword and press the Enter key.
Use the navigation keys to enter a new password. To erase a character, press and
hold the Up Arrow (▲) and Down Arrow (▼) keys simultaneously. If no password is
selected (all characters erased during password selection through the password select
menu), the user will not be prompted with a logon dialog during web page initialization.
The Java Applet uses a UDP socket to communicate with the RCP. If you are using a
hardware or software firewall, it will need notification that the Applet is authorized. If the
firewall is not notified, the UDP packets will be blocked.
The RCP Monitor and Control is performed via following the links on the web page.
These links include Status and Faults, Communication Settings, Settings, and Fault
Setup.
• Status and Faults: A view of all faults and operational parameters.
• Communication Settings: This tab provides access to all communication
related settings. From here, the user can change the IP settings, Interface,
Protocol, Baud Rate, Password and SNMP settings.
• Settings: Read/Write listing of most adjustable RCP parameters. All options
are selectable. To set a parameter, select the new value and click the
“Change” button with the mouse pointer.
• Fault Setup: All fault related settings are available under this tab.
Note: Only one web browser should be connected at any time. If a second browser
connects to the same RCP Web Interface, service quality cannot be assured.
Important! Make sure to set the IP Port Address to 1007. The Web interface will
not function properly with a different port address selection. If the Web interface
has to be disabled for any reason, select a port address of any other value.