Specifications

Operations Manual, Redundant System Controllers 209351 REV B 85
Data
Address
# Bytes Description Limits and valid values
1 2 LNA unit 1 calibration Data
LNA unit1 cal. Point conversion: 0.57 mA per
1 value increment, maximum value =1023.
2 2 LNA unit 2 calibration Data
LNA unit2 cal. Point conversion: 0.57 mA per
1 value increment, maximum value =1023.
3 2 LNA unit 3 calibration Data
LNA unit3 cal. Point conversion: 0.57 mA per
1 value increment, maximum value =1023.
Table 7-8: System Threshold Data Values
Data
Address
# Bytes Description Limits and valid values
0 2
Current value of ADC
channel 0
LNA unit3 power supply’s current. 0.57 mA
per 1 ADC increment, maximum ADC value
=1023.
1 2
Current value of ADC
channel 1
LNA unit2 power supply’s current. 0.57 mA
per 1 ADC increment, maximum ADC value
=1023.
2 2
Current value of ADC
channel 2
LNA unit1 power supply’s current. 0.57 mA
per 1 ADC increment, maximum ADC value
=1023.
3 2
Current value of ADC
channel 3
Power Supply 2 output voltage. 36 mV per 1
ADC increment, maximum ADC value =1023.
4 2
Current value of ADC
channel 4
Power Supply 1 output voltage. 36 mV per 1
ADC increment, maximum ADC value =1023.
5 2
Current value of ADC
channel 5
Not Used
6 2
Current value of ADC
channel 6
Not Used
7 2
Current value of ADC
channel 7
Not Used
Table 7-9: ADC (Analog-Digital Converter) Addressing