Specifications

84 209351 REV B Operations Manual, Redundant System Controllers
Data
Address
# Bytes Description Limits and valid values
1 1 Unit 1 Fault state No Fault = 0; Fault = 1; Ignored = 2
2 1 Unit 2 Fault state No Fault = 0; Fault = 1; Ignored = 2
3 1 Unit 3 Fault state No Fault = 0; Fault =1; Ignored = 2
4 1 Summary Fault No Fault = 0; Fault = 1
5 1 Power Supply 1 Fault State No Fault = 0; Fault = 1
6 1 Power Supply 2 Fault State No Fault = 0; Fault = 1
7 1 Auxiliary input Fault State No Fault = 0; Fault = 1; Ignore = 2
8 1 External Port State
Bit 0-2 = SSPA Input lines
Bit 3-8 = Auxiliary Input lines
9 1 LNA Faults
Bit 0 = 1; Faults enabled; Bit 0 = 0; Faults disabled; Bit 1 =
1; Unit 1 Fault; Bit 2 = 1; Unit 2 Fault; Bit 3 = 1; Unit 3
Fault; Bits 1-3 = 0; No Fault
10 1 SSPA Faults
Bit 0 = 1; Faults enabled; Bit 0 = 0; Faults disabled; Bit 1 =
1; Unit 1 Fault; Bit 2 = 1; Unit 2 Fault; Bit 3 = 1; Unit 3
Fault; Bits 1-3 = 0; No Fault
11 1 RF Switch 1 position
Switch Fault = 1; Switch Ignore = 2; Position 1 = 3;
Position 2 = 4
12 1 RF Switch 2 position
Switch Fault = 1; Switch Ignore = 2; Position 1 = 3;
Position 2 = 4
13-14 2
Forward RF Power
(available only with systems equipped
with Forward RF power meter)
If Setting RF Power Units = 0, Value x 10dBm;
If Setting RF Power Units = 1, Value x 10 W;
(See Table 16, Data Address 21 for details)
(-100 for N/A (0xFF9C); Low Byte First (version 3.10)
15-16 2
Ambient Temperature in (
o
C)
(available only with systems equipped
with Forward RF power meter)
Value x 1 °C
N/A=0xFF9C (if parameter is not available at present
time); Low Byte First (version 3.10)
17-18 2
Core Temperature of SSPA Unit 1
(available only with systems with remote
SSPA control enabled)
Value x 1 °C
N/A=0xFF9C (if parameter is not available at present
time); Low Byte First (version 3.10)
19-20 2
Core Temperature of SSPA Unit 2
(available only with systems with remote
SSPA control enabled)
Value x 1 °C
N/A=0xFF9C (if parameter is not available at present
time); Low Byte First (version 3.10)
21-22 2
Core Temperature of SSPA Unit 3
(available only with systems with remote
SSPA control enabled)
Value x 1 °C
N/A=0xFF9C (if parameter is not available at present
time); Low Byte First (version 3.10)
23-24 2
Reflected RF Power
(available only with systems equipped
with Reflected RF power meter)
If Setting RF Power Units = 0, Value x 10dBm;
If Setting RF Power Units = 1, Value x 10 W;
(See Table 16, Data Address 21 for details)
(-100 for N/A (0xFF9C); Low Byte First (version 3.30)
25-26 2
DC Current
Unit 1 in Amps
Value x 10 Amp
N/A=0XFF9C; Low Byte First (version 3.60)
27-28 2
DC Current
Unit 2 in Amps
Value x 10 Amp
N/A=0XFF9C; Low Byte First (version 3.60)
29-30 2
DC Current
Unit 3 in Amps
Value x 10 Amp
N/A=0XFF9C; Low Byte First (version 3.60)
31-32 2
Forward RF Power
Unit 1 in dBm
Value x 10 dBm
N/A=0XFF9C; Low Byte First (version 3.60)
33-34 2
Forward RF Power
Unit 2 in dBm
Value x 10 dBm
N/A=0XFF9C; Low Byte First (version 3.60)
35-36 2
Forward RF Power
Unit 3 in dBm
Value x 10 dBm
N/A=0XFF9C; Low Byte First (version 3.60)
Table 7-7: System Condition Data Values