Specifications
Operations Manual, Redundant System Controllers 209351 REV B 83
Table 7-6: System Settings Data Values
Data
Address
# Bytes Description Limits and Byte Values
1 1 System Configuration
1:2 Controller = 0; 1:1 Controller = 1;
Phase combine 1:1 = 2; Dual 1:1 Controller = 3
2 1 Switching mode Auto Mode = 0; Manual Mode =1
3 1 Control mode Local = 0; Remote = 1
4 1 Reserved N/A
5 1 Priority Select Pol1 = 0; Pol2 = 1
6 1 Communication Protocol* Normal=0; Terminal=1** (version 4.00)
7
1 Baud Rate* 9600 = 0; 2400 = 1; 4800 = 2; 19200 = 3; 38400 = 4
8 1 Unique network address Valid values: 0 – 255
9 1
Type of serial interface*
RS232 = 0; RS485 = 1;
IPnet=2; SNMP=3 (version 4.00)
10 1 Type of fault monitoring LNA only = 1; SSPA only = 0; Both = 2
11 1 Auxiliary fault monitoring Monitor = 0; Ignore = 1
12 1 RF Switch Monitoring Major Fault=0, Alert Only=1, Alternate=2 (version 3.30)
13 1 Fault Latching Latch Enable=0, Latch Disable=1
14 1 Fault Window 20%=0, 8%=1, 12%=2, 15%=3
15 1 Fault Logic Fault on Low=0; Fault on High=1
16 1 User Password Valid Values=0 to 255
17 1 Amplifier Standby Configuration
Amplifier 2 on Standby=0 (default)
Amplifier 1 on Standby=1
Amplifier 2 on Standby=2
Amplifier 3 on Standby=3 (combine in FPRC-1100 mode)
18 1 Buzzer Enable Buzzer=0; Disable Buzzer=1
19 1 Password Protection Protection Off=0; Protection On=1
20 1 System Type None=0; Compact Outdoor=1; Rack Mount=2; vBUC=4
21 1 RF Power Units
Measure RF in dBm = 0;
Measure RF in Watts = 1 (version 3.50)
22 1 Reserved N/A
23 1 LNA/LNB PS Output Voltage
Low range 13V, 900 mA = 0
High range 17V, 900 mA = 1
High Power Range 26V, 1.5A = 2 (v4.13 -HP version only)
24 1 Remote Response Address Valid Values= 0 to 255
25 1 Mute State Mute On=0; Mute Off=255
26 1 Remote SSPA Attenuation Valid Values= 0 to 255 (version 3.10)
27 1 Switch Mute Off=0; Internal=1; External=2; All on=3 (version 3.30)
28 1 Fault Tolerance Disabled=0; One Fault=1; Two Faults=2 (version 3.70)
29-32 4 IP Address (MSB – LSB)*
33-35 4 IP Gateway (MSB – LSB)*
36-40 4 IP Subnet Mask (MSB – LSB)*
41-42 2 Receive IP Port (MSB – LSB)*
43-46 4 IP Lock Address (MSB – LSB)*
47 - 49 3
Individual SSPA Unit Attenuation
Offset. Offset value will be added
to Remote SSPA Attenuation value
(Data Address 26) to form SSPA
final value of attenuation
Valid Values= 0 to 255 (version 4.20)
Settings required for normal operation of IP interface.
Consult network administrator for a proper setup.
All settings physically located on the RCP2-1000 unit.
Changes to these settings effective only after
controller restart. (version 4.00)
* - Requires hardware reset
** - Versions earlier than 4.00 support a different protocol selection:
Auto Select= 0; Extended = 1; Locus = 2; Terminal = 3