Specifications
Operations Manual, Redundant System Controllers 209351 REV B 57
Important! Real system output power most likely will be different from this parameter.
In 1:1 or 1:2 systems, losses in switching and waveguide systems are not accounted.
In phase combined systems, real output power will depend on the combining
configuration. For system output power, refer to FrwrdRF(Watts/dBm) on SSPA
subsystem info page 1.
SSPA sub system info page 3 (RCP firmware version 3.10 or better) pertains to each
individual SSPA unit’s core temperature and ambient temperature.
Ambient(C) – ambient temperature readout in °C. This readout is available only on the
systems equipped with forward RF power sensor, otherwise it will indicate N/A.
Unitx(C) – is an individual SSPA unit’s core temperature in °C. If a unit is not present
in the current system configuration, value will read N/A.
SSPA sub system info page 4 (RCP firmware version 3.60 or better) pertains to
individual SSPA unit’s DC current consumption.
UnitDCx(Amp) – DC current consumption of a SSPA unit, measured in Amperes. If a
unit is not present in the current system configuration, value will read N/A.
SSPA sub system info page 5 (RCP firmware version 3.30 or better) pertains to
additional subsystem settings.
System Type – is the type of connected SSPA subsystem. Possible readout: Compact
– for subsystem of Compact Outdoor SSPAs; RM – for subsystem of Rack Mount
SSPAs; and vBUC – for subsystem of vBUC amplifiers.
SWMute – is type of switch muting implemented on the current system. Off – no switch
muting; External – for external switch muting input; Internal – for switching associated
with this RCP unit; Both – utilization of switch muting inputs.