Specifications
52 209351 REV B Operations Manual, Redundant System Controllers
4.5.1 Configuring the RCP for Remote Control Mode
The RCP unit has to be configured to support remote control of the system. To do so,
perform the following steps:
1. Press the Main Menu key on the RCP front panel;
2. Select 5.Options and press the Enter key;
3. Select 6.More and press the Enter key;
4. Select 3.SSPA and press the Enter key;
5. Select 3.System Type and press the Enter key;
6. Select 2.RM SSPA if you want to control a system of Rack Mount SSPAs,
Select 3.CO SSPA if you want to control a system of Compact Outdoor
SSPAs, or Select 4.vBUC if you want to control a system of vBUC amplifi-
ers, then press the Enter key. To disable the remote control feature, select
1.None and press the Enter key;
7. Select 4.View and press the Enter key;
Your RCP unit is now ready to control a remote system. After the RCP unit is config-
ured to control a remote system, make sure the system is correctly wired. See Tables
4-1, 4-2 and 4-3 for proper wiring.
RCP2 J5 Serial Local SSPA1 M&C J4* SSPA2 M&C J4 SSPA3 M&C J4
1,9 (RX+; 120 Ohm Termination) T (TX+) T (TX+) T (TX+)
2 (RX-) E (TX-) E (TX-) E (TX-)
3 (TX-) F (RX-) F (RX-) F (RX-)
4 (TX+) U (RX+) U (RX+) U (RX+)
5 (Ground) B,V (Mute In, GND) B,V (Mute In, GND) B,V (Mute In, GND)
RCP2 J8 Ext. Alarm
SSPA1 M&C J4 SSPA2 M&C J4 SSPA3 M&C J4
1 (Ext. Alarm 1) b (Summary open on
fault)
2 (Ext. Alarm 2) b (Summary open
on fault)
3 (Ext. Alarm 3) b (Summary open on
fault)
4 (Ground) a (Summary
Common)
a (Summary
Common)
a (Summary
Common)
* If the cable length exceeds 50 ft., a termination resistor of 120 Ohms must be installed between F and U of the
SSPA1 M&C J4 connector.
Table 4-1: Compact Outdoor SSPA Wiring