Specifications
106 209351 REV B Operations Manual, Redundant System Controllers
settings
Table contents current device configuration and provides device management.
For detailed settings table info for SNMP device see Table 7-11 . Read/write
access for settingsValue column.
thresholds
Table provides information about device internal limits and subsystems info. For
detailed table information refer to Table 7-12. Read only access.
conditions
Table contents device fault status information. Read only access. For detailed
conditions table info see Table 7-13.
7.6.4.4 Configuring RCP2 unit to work with SNMP protocol
1. Set up the unit IP address. Perform the following procedure: Press the Main
Menu key on the front panel; select 2.Com.Setup and press the Enter key;
select 5.IP Setup and press the Enter key; select 2.LocalIP and press the
Enter key. Use the navigation keys to adjust the unit IP address. Press the
Enter key when complete;
2. Set up the unit gateway address. Perform the following procedure: Press the
Main Menu key; select 2.Com.Setup and press the Enter key; select 5.IP
Setup and press the Enter key; select 4.Gateway and press the Enter key.
Use the navigation keys to adjust the unit gateway address. If no gateway is
needed, set the address to 0.0.0.0. Press the Enter key when complete;
3. Set up the unit subnet mask. Perform the following procedure: Press the
Main Menu key; select 2.Com.Setup and press the Enter key; select 5.IP
Setup and press the Enter key; select 3.Subnet and press the Enter key.
Use the navigation keys to adjust the unit subnet mask. Press the Enter key
when complete;
4. Set up the unit Community Set and Get strings. Perform the following proce-
dure: Press the Main Menu key; select 2.Com.Setup
and press the Enter
key; select 5.IP Setup and press the Enter key; select 6.More and press the
Enter key; select 1.CommunitySet (or 2.CommunityGet). Using the navi-
gation keys to adjust the unit community strings information. Press and hold
the key for typematic option. Press the Enter key when complete. Press and
hold the Down Arrow (▼) key and then press the Up Arrow (▲) key to
erase unwanted characters;
5. Set up the unit interface to SNMP. Perform the following procedure: Press
the Main Menu key; select 2.Com.Setup and press the Enter key; select
4.Interface and press the Enter key; select 4.SNMP and press the Enter
key.
6. SNMP protocol now is set and ready to be used.