Specifications
Operations Manual, Redundant System Controllers 209351 REV B 105
7.6.4.3 Description of MIB entities
deviceINFO
This field includes general device information.
deviceID
Octet string type; maximum length -60; field specifies device model and serial
number; read only access; OID -1.3.6.1.4.1.20712.1.1
deviceLocation
Octet string type; maximum length 60; filed allow customer to store information
about device physical location or any other textual information related to the
device; read/write access; OID -1.3.6.1.4.1.20712.1.2
deviceRevision
Octet string type; maximum length 60; field specifies device firmware revision;
read only access; OID -1.3.6.1.4.1.20712.1.3
deviceType
Enumeration, integer type; field allows simple detection of SNMP device type.
Values: rmsspa(1), cosspa(2), rcp2fprc(3), rcp21000rm(4), rcp21000co(5),
rcp21000rcp(6), buc(7), rbc(8), minicosspa(9); read/write access. Setting the ID
to any other value will default type to cosspa. OID -1.3.6.1.4.1.20712.1.4
devices
This field is subdivided into 5 branches: paradiseDevice, paradiseDeviceA,
paradiseDeviceB, paradiseDeviceC and modem. The paradiseDevice branch
currently is used for all Paradise Datacom LLC SNMP enabled device except
Modem. See the Evolution Modem manual for specific MIB information. Branch-
es for Device A, B and C are reserved for future use.
paradiseDevice
Field contents tables hold specific device information: Settings, Thresholds and
Conditions. All table formats follow a common pattern: Index, Value, TextValue.
The threshold table has an additional column for parameter validation. The
conditions table has an extra column for event counters.
The Index column provides general table indexing; the Value column presents
the current value of the relevant parameter; the TextValue column provides
information about parameter name, measurement units and limits.
Value “1” in the validation column of the thresholds table indicates that relevant
parameter is valid under the current system configuration; value “2” indicates
that parameter is invalid or “Not available”.
The event counter column of the conditions table indicates how many times a
value of a relevant parameter changed its state since system power-up.